One home, unit or business
Tell us what the panel serves, the reason for replacement and any planned equipment changes. We will discuss the feeder, affected circuits and access for that location.
Discuss one subpanelElectrical services / Greater Los Angeles
Whether the job involves one panel or hundreds of units, the scope needs to account for the feeder and the circuits it serves. We assess existing equipment, planned loads and access before defining the replacement work.
Request a subpanel assessment
Tell us what the panel serves, the reason for replacement and any planned equipment changes. We will discuss the feeder, affected circuits and access for that location.
Discuss one subpanelStart with the approximate unit count, any recurring panel types and the property contact who can coordinate access. A scope review can identify differences between unit layouts before a rollout is planned.
See how a multi-unit program is scopedAn occupied-building program needs agreement on the electrical work and the practical details of entering each unit. These are the decisions we review with the property team.
| Decision | What to establish | Who contributes |
|---|---|---|
| Representative units | Panel types, unit layouts and known differences that could change the scope. | Property records and an electrical site assessment. |
| Feeders & circuits | Existing supply, upstream protection, affected circuits and any work beyond the cabinet. | Electrical assessment; engineering input where needed. |
| Access & notices | Unit-entry arrangements, occupant contacts and the proposed sequence before dates are agreed. | The owner, manager or HOA and the project team. |
| Walls & finishes | Who handles opening, patching, painting and finish restoration, and what the proposal includes. | The property team, electrical contractor and other trades. |
| Handoff records | Circuit directories, unit-by-unit completion records and applicable inspection closeout. | The electrical contractor and the designated property contact. |
A larger panel does not increase the capacity of the feeder supplying it. We review the existing supply, upstream protection, equipment condition and circuit arrangement before recommending a replacement. Where an approved repair is practical, that can be discussed alongside replacement.

In a multifamily property, subpanels may serve individual apartments, house loads or shared equipment. We identify what will be affected and coordinate access with the owner, manager or HOA representative. If the project also involves meters, switchgear or the main service, the scope should show how the work fits together.
Our Culver City project included approximately 350 in-unit subpanel replacements within a larger 14-building and clubhouse upgrade. The Los Feliz project included nine subpanels and eight meters.
The Los Feliz photographs below document the exterior metering work. The subpanel quantities describe the confirmed project scope, rather than what is visible in those photographs.
If you need an additional panel rather than replacement of an existing one, see new subpanel installation. For a written carrier request, see insurance-requested electrical work.
From our project photographs
This completed multifamily electrical project involved eight meters and nine subpanels. The photographs show wall preparation, conduit connections and the installed meter equipment.



That depends on the existing main panel, feeder and proposed loads. A subpanel issue does not automatically require a main-panel replacement. We review the connected equipment and explain whether the work needs to extend upstream.
Yes. We handle in-unit and house subpanel work for multifamily properties. The number of panels, access arrangements and building distribution determine the installation sequence and any interruption plan.
Sometimes an approved repair is available, but compatibility and condition must be checked for the exact equipment. Physical fit alone does not establish whether a component is suitable.
BEFORE WE QUOTE THE WORK
Feeder conductors, upstream protection, enclosure condition and intended loads need review. A larger replacement cabinet does not automatically permit a larger load. Corrections may extend beyond the panel itself.
Specify compatible equipment and a useful circuit directory. Clarify circuit identification, testing, affected loads and whether permits or feeder work are included. That makes the scope easier to compare and the installation easier to maintain.